Skip to content

Your cart is empty

Have an account? Log in to check out faster.

Continue shopping

Stage Lighting Buying Guide: Fixtures, DMX & Power

Choose stage lighting by job first, then by DMX channels and power. A DMX universe carries 512 channels, so a 24-channel fixture mode allows 21 fixtures. A 16 A / 230 V circuit carries 3680 W, which is 12 fixtures at 300 W each.

Decide what each fixture is for

Lighting arguments usually start with wattage and should start with purpose. Four families cover almost everything on a stage.

  • Beam – a narrow, near-parallel shaft that stays visible in haze. Aerial looks, not useful for lighting faces.
  • Spot – a focusable pool with gobos, iris and framing. This is what lights performers and scenery.
  • Wash – wide, soft colour coverage. Fills the stage and the backdrop.
  • Effect and static fixtures – bars, strobes, blinders and matrix panels that build the picture around the moving fixtures.

A rig of six beams looks impressive in a photograph and leaves the band in the dark. Most small stages need wash and spot coverage first, then beams for effect.

How many fixtures does a stage need?

Plan across the width, not by floor area. A common starting point is one fixture every 1.5 to 2 m along each truss.

Worked example: an 8 m wide stage

  • Front truss at 2 m spacing: 8 / 2 = 4 fixtures for key light
  • Back truss at 2 m spacing: 4 fixtures for backlight and effect
  • Plus effect fixtures along the back for the picture, typically 6 to 8 bars

That is 8 moving heads and 8 effect fixtures for a modest stage, which is the point at which power and DMX planning stop being optional.

DMX: count channels before you count fixtures

DMX512, standardised as ANSI E1.11, carries 512 channels in one universe. Every fixture consumes channels according to the mode you select.

fixtures per universe = 512 / channels per fixture

Channel mode Fixtures per DMX universe (512 ch) Units in this range using it
4 channels 128 2
5 channels 102 1
6 channels 85 2
7 channels 73 2
8 channels 64 2
10 channels 51 1
12 channels 42 3
15 channels 34 1
16 channels 32 1
24 channels 21 1
28 channels 18 1
30 channels 17 1

Fixtures with more channels give finer control — separate colour, gobo, prism and movement attributes — and cost you universe capacity. Most fixtures offer several modes, which is a genuine trade rather than a specification quirk.

When one universe is not enough, Art-Net and sACN carry multiple universes over standard network cable to nodes that break out DMX at the truss. The node count is part of the design, not an accessory.

Power: this is what actually limits a rig

A 16 A circuit at 230 V carries about 3680 W. Here is what the fixtures in this range actually draw.

Fixture family Units with published power Lowest Median Highest Fixtures per 16 A / 230 V circuit (at median)
LED Effect Light 23 10 W 250 W 3000 W 14
Special Effects 21 200 W 1500 W 6000 W 2
Moving Head Light 18 12 W 600 W 1650 W 6
Laser Light 6 12 W 450 W 600 W 8

The median moving head here draws 600 W, so six fill a 16 A circuit before any headroom. The median special effects machine draws 1500 W, so two fill a circuit. Effect machines with heaters also draw more during warm-up than their running figure suggests.

Worked example: the 8 m stage above

  • 8 moving heads at 600 W = 4800 W
  • 8 effect bars at 250 W = 2000 W
  • Total 6800 W, which is two 16 A circuits minimum and sensibly three

Ingress protection

A fixture with no published IP rating belongs indoors or under cover. Ratings are defined in IEC 60529 and must be published for the specific model; they are not inherited from the rest of a range. Outdoor stages and uncovered truss positions need rated fixtures.

Rigging and electrical safety

Fixture weights and loads quoted here come from product specifications and are for planning only. Load ratings must be verified against the manufacturer’s load table and signed off by a qualified rigger. Electrical distribution should be designed and installed by a competent person, and circuit figures in this article assume a nominal 230 V supply.

Light sources: what the wattage does not tell you

A 200 W LED engine and a 200 W discharge lamp are not comparable, and neither figure describes the light that reaches the stage. Optical efficiency, lens design and colour mixing method all sit between the source and the output.

LED sources dominate current fixtures for practical reasons: no lamp to replace, lower power draw for a given output, instant on and off, and dimming without colour shift in better designs. Discharge sources still appear where very high intensity from a small aperture is needed, at the cost of lamp life, warm-up time and a fan that never stops.

Colour mixing divides into additive systems that combine coloured emitters and subtractive systems that filter white light through moving flags. Additive mixing is standard in LED wash fixtures; subtractive mixing appears in profile and spot fixtures where a single bright source has to stay collimated.

Gobos, prisms and the rest of the optical train

A spot fixture's usefulness comes from what it can do to the beam. Static gobo wheels carry fixed patterns; rotating gobo wheels add movement; prisms split the beam into multiple images; iris controls the beam diameter; frost softens the edge.

Each of these consumes DMX channels, which is the hidden cost of a feature-rich fixture. A fixture with two gobo wheels, a prism, an animation wheel and framing shutters is wonderfully capable and will use 30 or more channels, which changes your universe plan.

Colour temperature and rendering on camera

If the stage is being filmed, colour quality stops being a matter of taste. Fixtures that produce an uneven spectrum can render skin tones poorly on camera even when they look acceptable to the eye, and mixing fixtures of different colour temperature across a front wash produces visible inconsistency in the recording.

Where the published data exists, keep front light fixtures matched to each other and check how they behave at the dimmer levels you actually use, since colour shift on dimming varies considerably between designs.

Rigging practicalities

Fixture weight determines what a truss can carry and how many crew are needed to get it there. A 600 W moving head is typically a two-person lift at height, and a truss loaded to its limit with heavy fixtures has no capacity left for anything else that gets added later.

Safety bonds are standard practice on every flown fixture as secondary suspension. Clamp type has to match the truss diameter. Both are items that get forgotten in an order and then delay a load-in.

Control: consoles and what they imply

A fixture is only as useful as the control behind it. A simple rig of static fixtures can run from a basic DMX controller. A rig of moving heads with gobo and colour attributes needs a console with fixture libraries and effect generation, and that is a significant purchase and a significant learning curve.

Two practical points: confirm the console's universe output matches your channel count, and confirm your fixtures exist in its library or can be patched manually without losing attributes.

A worked budget for a small venue rig

An 8 m stage, indoor, with camera coverage for streaming:

  • 8 moving heads for key and back light, median 600 W each: 4800 W, 2 universes if in a 24-channel mode (192 channels, so comfortably 1)
  • 8 LED bars for the back picture, 250 W each: 2000 W, 64 channels in a simple mode
  • 1 hazer, median 1500 W for the special effects family: 1500 W
  • Total: 8300 W, which needs three 16 A circuits as an absolute minimum and sensibly four
  • Total channels: 256 + 64 = 320, which fits one universe with room to grow

Note which constraint binds first. The channel count is comfortable; the power is not. That is the usual pattern in small venues.

Common mistakes

  • Buying beams before wash. Impressive photographs, badly lit performers.
  • Ignoring warm-up draw on effect machines. Heaters pull more than the running figure.
  • Picking the largest channel mode by default. It silently costs universe capacity.
  • Forgetting clamps and safety bonds. The rig cannot go up without them.
  • Mixing colour temperatures across a front wash. Invisible live, obvious on camera.

Decision criteria

  • If the stage has no front light, buy wash and spot fixtures before beams.
  • If you are past 20 fixtures, plan Art-Net or sACN rather than squeezing modes.
  • If the venue supply is 16 A sockets, divide 3680 by your fixture wattage and respect the answer.
  • If any fixture is uncovered outdoors, require a published IP rating.
  • If you want visible beams, budget for a hazer; without atmosphere there is nothing to see.

Browse Stage Lighting, Moving Heads, LED Effect Lights and Special Effects.

Sources

  • ANSI E1.11 (ESTA) defines DMX512-A, the control protocol referenced here.
  • IEC 60529 defines the ingress protection code.
  • Power and channel figures come from the product data published for fixtures listed in this store.

Frequently asked questions

How many moving heads do I need for a stage?
Plan across the width at roughly one fixture every 1.5 to 2 m per truss. An 8 m stage typically takes four on the front truss and four on the back.

How many fixtures fit in one DMX universe?
Divide 512 by the channel count of the mode you choose. A 24-channel mode gives 21 fixtures, a 16-channel mode gives 32, and a 12-channel mode gives 42.

How many lights can I run on one 16 A circuit?
A 16 A circuit at 230 V carries about 3680 W. At the 600 W median for moving heads in this range that is six fixtures, and you should leave headroom below that.

What is the difference between beam, spot and wash?
Beam gives a narrow visible shaft for aerial effect, spot gives a focusable pool with gobos for lighting people, and wash gives wide soft colour coverage.

Do I need an IP-rated fixture outdoors?
If the fixture is uncovered, yes. A fixture with no published ingress protection rating under IEC 60529 should be treated as indoor or covered-position only.

Do I need haze for beam fixtures?
Yes, to see the beam in the air. Without haze or fog the audience only sees where the light lands, not the shaft itself.

Sources & Methodology

Our editorial content is produced through hands-on evaluation and cross-referenced against established industry sources. We do not publish sponsored rankings or accept payment to feature products.

  • RTINGS.com — Objective audio measurements, ANC performance, frequency response data
  • SoundGuys — Lab-tested audio reviews and earbud comparisons
  • Manufacturer specifications — Official product datasheets and technical documentation from brand websites
  • Soundmali editorial testing — Hands-on evaluation by our team. Last reviewed: November 2026

Featured Collection

Stage Lighting

Stage lighting divides into fixtures that move and fixtures that stay still....

Shop Now

More from Guides

Search